2007-08-25 - Identified by Jeff Scofield through information in Möller factory documents. -Database Manager
2010-10-12 - Updated through online information from John Dill. -- In the last twenty years this instrument has been plagued with water damage, bees, wasps, one squirrel, and extreme low humidity in the Winter. The Choir bellows was replaced and moved to the opposite side of the chamber since there was a chronic water leak that destroyed the original. Condensation from the air-conditioning destroyed the original bellows that was fed by the original blower from the original Kilgen organ and also had to be replaced, the blower was retained. The Choir division has had numerous ciphers repaired and pallets replaced due to water damage. The instrument is now at peace and all seems to be working well. All the original water leaks have been addressed, be it with a few extreme solutions, and humidifiers have been placed inside the organ chambers to prevent the humidity from ever dropping below 40/50%. In 2005 Ardmore had record low humidity bleow 6% and when the heat came on in the church one toe board in the Great cracked at least 12 inches. The instrument was very well built and is now in good playing order. In 2000 when the organ was ten, a Zymbelstern was added. This instrument also has the original "Harp" from the previous organ. No alterations or additions to the stop list have been made with the exception of the Zymbelstern. -Database Manager
2011-08-04 - Updated through online information from Jerry Bell. -Database Manager
2012-04-06 - Updated through online information from Jeff Scofield. -Database Manager
2016-05-22 - Updated through online information from Jeffrey Schleff. <br>An 8 foot Tuba recently was added to the organ's Positive Division -Database Manager
Stoplist copied from the factory specifications Source: Source not recorded Date not recorded
Ardmore, Oklahoma First Presbyterian Church Möller Op. 11812 1991 3/28 _____________________________________________________ GREAT CHOIR 16' Rohrgedeckt pf a 8' Holzgedeckt 61 8' Principal 61 8' Erzähler Celeste II 110 8' Bordun 61 4' Spitzflöte 61 4' Octave 61 2' Principal 61 2' Waldflöte 61 1 1/3' Quintflöte 61 III-IV Mixture 224 8' Krummhorn 61 Sub Tremulant Super Sub 8' Festival Trumpet CH Unison Off Chimes pf Super Harp 49 SWELL 16' Festival Trumpet tc 8' Rohrflöte 61 8' Festival Trumpet pf 8' Viole 61 8' Viole Celeste 49 PEDAL 4' Spitzprincipal 61 32' Resultant -- 2' Blockflöte 61 16' Principal 32 II Sesquialtera 98 16' Rohrgedeckt 12 III-IV Scharf 208 8' Octave 12 8' Trompette 61 8' Rohrflöte SW Tremulant 4' Choralbass 12 Sub 16' Contre Trompette 12 SW Super 4' Clairon SW 8' Festival Trumpet CH a to be from SW 8' Rohrflöte and PD 16' Rohrgedeckt [Received online from Jeff Scofield April 1, 2012]
Regrettably, it is not possible to display the information about the sponsor of this pipeorgandatabase entry or if there is a sponsor. Please see About Sponsors on Pipe Organ Database.